www.kc2healthsupplies.com.au

Login Form

Bolsaplast Self Sealable Pouches
AU$25.00 ex GST

These sterilisation pouches are self-sealing and are used for packing medical devices and other materials that require sterilisation by steam, ethylene oxide or formaldehyde. 
Product is packed and supplied as follows:
MBA1082 – MBA1086: 1200 pieces/unit     MBA1088-MBA1089: 800 pieces/unit
MBA1090: 400 pieces/unit 

REORDER

DESCRIPTION

PCS/ UNIT

UNITS/ CTN

MBA1080

75mm x 200mm «

200

6

MBA1081

90mm x 200mm «

200

6

MBA1082

90mm x 230mm

200

6

MBA1084

100mm x 240mm  «

200

6

MBA1085

130mm x 250mm

200

6

MBA1086

130mm x 330mm

200

6

MBA1087

140mm x 280mm «

200

4

MBA1088

200mm x 330mm

200

4

MBA1089

250mm x 400mm «

200

4

MBA1090

300mm x 390mm

400

1

MBA1091

300mm x 450mm «

200

1

Construction

Paper/Laminate packaging constructed of paper on one side and Laminate on the other. Laminate is composed of PET/PP.It has three process indicators: steam, ethylene oxide and formaldehyde.
Paper Properties Laminate Properties
Grammage–60g/m2 Total thickness-52μm
Dry Tensile Strength (MD) -6.1 kN/m -Polyester-12μm
                              (CD)-3.3kN/m -Polypropylene-40μm
Wet Tensile Strength(MD)-2.1 kN/m Elongation at break   -L > 30 N/15 mm
                                      (CD)-1.3 kN/m           - T > 25 N/15 mm
Burst Strength Dry -320 kPa Minimum sealing temperature -170°C
Burst Strength Wet -140 kPa Maximum sealing temperature -210°C
Tear Strength (MD)-630mN
Tear Strength (CD)-670mN
Water Repellency-35 seg 
COBB test (60s)-15g/m2
Seal strength - >1.5 N/15mm
Pore size -18 μm
Bendtsen Porosity -700 ml/mn
Air permeance - 8 μm/Pa.s
pH water extract – 5 – 8
Chloride Content (Nacl) - < 0.05%
Sulphate Content -< 0.25%
Fluorescence -0
Other Properties
Latex free
Excellent peelability and fibre-free
Chevron sealing for a better peeling
Sealing in both sides, 3-channel for a better protection
CE certified
Complies to EN868-5, ISO11607-1, AS1079-4
Shelf life-4 years from manufacture date
ARTG Number:127638
VALIDATION:
It is the responsibility of the user to validate the single packaging in accordance with local regulatory requirements since product is considered a component of the Medical Device.

Recommended Storage

Pre sterilisation:
Store in a cool and dry place away from direct sunlight. Recommended storage temperature is 10ºC -30ºC and relative humidity 30-70%.
Post sterilisation:
If the sterilisation pack is stored under ideal storage conditions, the indicator ink colour will remain unchanged for up to 2 years.

Packaging

Product is packed and supplied as follows:
MBA1082 – MBA1086: 1200 pieces/unit     MBA1088-MBA1089: 800 pieces/unit
MBA1090: 400 pieces/unit

Instruction of Use

These sterilisation pouches are self-sealing and are used for packing medical devices and other materials that require sterilisation by steam, ethylene oxide or formaldehyde.